GENERAL INFORMATION



For the cooling system, a forced water-cooling circulation method is adopted and it has the following features.


SPECIFICATIONS


Item
4A9
4B10,
4B11-Non-turbo
BWC
4B11-Turbo
Cooling method
Water-cooled pressurized, forced circulation with electrical fan
Water pump
Type
Centrifugal impeller
Drive method
Drive belt
Timing belt
Drive belt
Thermostat
Type
Wax pellet with jiggle valve
Valve open temperature °C
82 ± 2
82 ± 1.5
87 ± 2
76.5 ± 1.5
Radiator
Type
Pressurized corrugate type
Core size (width × height × thickness) mm
700 × 408.6 × 16
700 × 408.6 × 16*1
700 × 408.6 × 27*2
Fin pitch mm
1.25
1.25*1
1.3*2
Performance kJ/h
222,600
222,600*1
254,000*2
A/T fluid cooler
Type
Double tube type
-
Performance kJ/h
5,220
-
Engine coolant
Specified coolant
DIA QUEEN SUPER LONG LIFE COOLANT or equivalent
BASF Glysantin Alu Protect Premium/G30
DIA QUEEN SUPER LONG LIFE COOLANT or equivalent
Quantity L
6.0 (including 0.65 L in the radiator condenser tank)
7.0 (including 0.65 L in the radiator condenser tank)
7.5 (including 0.62 L in the radiator condenser tank)
7.0 (including 0.65 L in the radiator condenser tank)
note
  • *1: Vehicles for EUROPE.
  • *2: Vehicles for RUSSIA.

CONSTRUCTION DIAGRAM


<4A9>

<4B10, 4B11-Non-turbo>

<BWC>

<4B11-Turbo>