Q.
Are the check results normal?
|
|
Repair or replace the connector.
|
|
|
|
- Check oxygen sensor (front) itself (Refer to ).
|
|
Q.
Is the check result normal?
|
|
Replace the oxygen sensor (front).
|
|
|
|
- Check oxygen sensor (rear) itself (Refer to ).
|
|
Q.
Is the check result normal?
|
|
Replace the oxygen sensor (rear).
|
|
|
|
Q.
Is the check result normal?
|
|
Repair or replace the connector.
|
|
|
|
- Disconnect engine-ECU connector, and connect special tool
power plant ECU check harness (MB992110) to measure at connector for inspection.
- Ignition switch: ON
- Voltage between terminal No. 39 and earth.
|
|
Q.
Is the check result normal?
|
|
- Check earthing line for short circuit.
|
|
Q.
Is the check result normal?
|
|
Repair the damaged harness wire.
|
|
|
|
- Check output line for short circuit.
|
|
Q.
Is the check result normal?
|
|
Repair the damaged harness wire.
|
|
|
|
- Reconfirmation of diagnosis code.
|
|
Q.
Is the diagnosis code set?
|
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ).
|
|
|
|
- Disconnect engine-ECU connector, and connect special tool
power plant ECU check harness (MB992110) to measure at connector for inspection.
- Ignition switch: ON
- Voltage between terminal No. 41 and earth.
|
|
Q.
Is the check result normal?
|
|
- Check earthing line for short circuit.
|
|
Q.
Is the check result normal?
|
|
Repair the damaged harness wire.
|
|
|
|
- Check output line for short circuit.
|
|
Q.
Is the check result normal?
|
|
Repair the damaged harness wire.
|
|
|